The Basic Principles Of Dp50rb
The Basic Principles Of Dp50rb
Blog Article
Web page 45 Return “Printer Service” web page, Pick out the corresponding service within the printer listing and raise the assistance. The procedure integrates drivers of HP printers, just after HP printers are related, drivers will probably be set up routinely (about 10s).If auto installation fails, icon will Display screen on the right lessen corner of the display screen to alert you that manual set up is necessary. Webpage forty six: Community Preset
The consumer isn't permitted to open up the covers and panel of the program, neither Take note: system disassemble is allowed. To make sure the system performance and security, only Mindray engineers or engineers approved by Mindray can perform upkeep.
3. Click on the higher icon during the display (prompts “Update” if you set the cursor on it), the update stage is performed, if fails, please deliver to R&D Heart. Determine 6-one Major Keep track of Servicing Display 4. Immediately after update is successful, restart the equipment soon after electrical power off to help make the info successful. HDD Partition ... Website page ninety one structured report linked facts file and DICOM viewing application Report report template obd.bin OBD knowledge file Model.txt Model file Comment Comment file AnatomyImage Anatomical pictures Measurement Measurement library Doppler method and connected boot configuration principal file and plug-ins, remote desktop server Multilanguage string file exe videoplay.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
By continuing your take a look at on our Web site, you might be consenting to our use of cookies. However, you'll be able to modify your cookie settings Anytime. Cookie preference Settle for and Commence
After you cease the scanning along with the image capture, you must electricity off the procedure and disconnect the program in the AC electric power supply, then pull out AC energy cables. Page 109: Battery Connecting Board
The chapter supplies the method to confirm primary operate and efficiency of product or service. This can be only employed for reference, not preventive execution. Functionality checking and tests of the section shall be completed by Mindray support engineers as well as consumer alongside one another. Web site 66: Standard Exam
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
Analyzing patients in currently’s demanding setting demands progressive technology that allows clinicians to produce speedy and self-confident diagnoses. The flexibility with the DP-50 expands your clinical utility when assisting to strengthen individual care.
five.2.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy Take a look at Action: Do changes as how in testing the most depth. Report the gap by 20mm Every segment over the longitudinal targets line utilizing the measurement caliper; Pick out the value with the best mistake (to 20mm), estimate the precision utilizing the method under The measurement caliper need to be positioned in the upper edge of the target, NOTE:... Web site seventy nine Transverse geometric positioning accuracy Exam Action: Address the scan surface of the phantom with drinking water or pair gel, gently contact the probe With all the scan surface area Modify the depth, earning the transverse targets to get displayed while in the impression. Adjust the main focus position being posited beside the transverse targets (the standard is not very clear) Modify parameters like acquire, TGC, creating Each individual transverse targets to become Evidently displayed. Page 80 five.5.2.4 Blackout Region Exam Phase: Go over the scan area on the phantom with drinking water or few gel, Carefully Speak to the probe with the scan floor Alter the depth in a lessen benefit, and established the main focus at the closest location to the scan surface area. Lower the value of parameters like AP, Get right until the track record noise just might be seen. Web page 81: Software Upgrade And Upkeep
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
.. Website page 161 The indicator to the printer Glitches happen when the adapter turns orange, along with the printing printer adapter runs. Disconnect and join the fails. electricity adapter, ability on the printer adapter again, and confirm whether the printing is ordinary soon after one moment. Page 163: Electrical Security Inspection
Overall performance Examination five.5.one Exam Course of action Resolution Detection depth Geometric Situation Accuracy Blackout region test History the exam photographs 5.5.two Test Content material The impression utilized here is only for reference, stick to the impression impact in the actual Notice: predicament. Prerequisites: Show: set the contrast and brightness on the medical application price (or the default status) Operation setting: darkish place, simulating the medical application atmosphere. Web page seventy six In problem which the transverse resolution screening targets are horizontally exhibited, document the minimal distance of two targets which can be Obviously identified. Repeat the operation higher than for your transverse resolution screening targets at other depths. As demonstrated in figure under. Axial resolution ... Web page seventy seven When using the convex probe, retain the transverse resolution tests targets to notice: be exhibited close to the midline. When employing a linear probe with steer function, usually do not turn on the steer functionality when conduct the transverse resolution exam. Zoom within the region in which the targets Situated if required. The diameter with the goal place at a particular depth is equal on the transverse resolution at the depth. Page seventy Dp50rb login eight 5.
Soon after replacing the CPU module, crucial file have to be produced Once more according to the new MAC handle and penned into HDD of your device. Or else, the configuration operate in the solution will likely be misplaced. Following removing the CPU module, Eliminate panhead screws with washers (12 M3X6) mounted on the main device box, you may take off the board. Web page 118 Figure eight-29 Disassemble the User interface Assembly (one) Maintain the higher edge of control panel assembly, and open up the control panel. Determine eight-thirty Disassemble the User interface Assembly (two) Immediately after eliminating just one countersunk head self-tapping screw PT3X10 mounted over the control panel and choose out the plug from the keyboard and the main device connecting cables, you may take out the control panel assembly.
Observe: Ensure that you could possibly pull out and thrust into your IO board sockets vertically when pulling out and assembling the IO board assembly on the place in the manage. Take away panhead screws with washers M3X6 (four) utilized to safe the IO board, after which you might get out the IO board. Webpage 116 Eliminate panhead screws with washers (two M3X6) that happen to be mounted on the main device, consider out the higher baffle and then pull out two cables connecting the most crucial board to the power module assembly.