.. Webpage 161 The indicator on the printer Errors arise once the adapter turns orange, along with the printing printer adapter operates. Disconnect and join the fails. electric power adapter, energy within the printer adapter again, and confirm whether the printing is standard following one moment. Web site 163: Electrical Protection Inspection

Information System Verify the battery periodically : a) Check if battery can be charged Commonly when electrical power-on: That The existing capacity is 100% or capacity boosts soon after a brief time implies which the battery can be billed Generally.

Tend not to use any cables aside from the cables presented Using the gadget by Mindray. three. Make use of the cable offered with This technique to connect the printer. Other cables may cause electrical shock. Site fifteen: Mechanical Security

The consumer is just not permitted to open the handles and panel of your system, neither NOTE: device disassemble is permitted. To ensure the program efficiency and protection, only Mindray engineers or engineers approved by Mindray can complete upkeep.

Find out superior diagnostic facts via prolonged perspective with the anatomical composition on all convex probes.

Return to the program preset interface. The option standing changes into Uninstalled. The uninstalling function is unique to inner end users.

Explore better diagnostic information by means of prolonged see of the anatomical structure on all linear probes

The DP-50 Skilled is definitely an progressive, large-efficiency Ultrasound Process engineered to assist you to have the insights you'll need. The Process’s powerful motor and high-velocity processing provide exceptional impression top quality and a complete data management Resolution.

Operate: About the back-end of the most crucial board, a Exclusive keep track of IC is applied to monitor sign voltages  and clock battery electrical power which might be supplied to the primary board by the principle device box power offer module.

The chapter provides the method to verify principal operate and overall performance of product. This is only useful for reference, not preventive execution. Functionality checking and tests of this aspect shall be carried out by Mindray company engineers as well as consumer with each other. Site sixty six: Normal Test

Page 45 Return “Printer Assistance” web page, Decide on the corresponding company from the printer checklist and improve the service. The technique integrates motorists of HP printers, right after HP printers are connected, motorists are going to be set up automatically (about 10s).If auto installation fails, icon will Show on the correct lessen corner from the monitor to warn you that manual set up is essential. Page forty six: Network Preset

Highest 4 moments tasking for one transmitted beam, resulting in great time resolution and higher frame rate.

Soon after replacing the CPU module, key file need to be produced Again in accordance with the new MAC handle and published into HDD on the equipment. Or else, the configuration function from the product will be dropped. Right after removing the CPU module, Take away panhead screws with washers (12 M3X6) mounted on the leading unit box, you might take from the board. Website page 118 Determine eight-29 Disassemble the User interface Assembly (one) Keep the upper edge of user interface assembly, and open up up the control panel. Determine 8-thirty Disassemble the Control Panel Assembly (two) Immediately after eliminating 1 countersunk head self-tapping screw PT3X10 preset over the control panel and get out the plug of the keyboard and the main device connecting cables, you could possibly get rid of the user interface assembly.

Performance Examination five.5.1 Check Process Resolution Detection depth Geometric Situation Precision Blackout region take a look at Record the exam visuals five.five.two Exam Articles The graphic used here is only for reference, stay with the impression effect in the real Notice: problem. Requirements: Show: set the distinction and brightness at the scientific software price (or perhaps the default status) Procedure environment: dim home, simulating the scientific application surroundings. Webpage 76 In affliction that the transverse resolution tests targets are horizontally exhibited, history the negligible length of two targets that can be Plainly acknowledged. Repeat Dp50rb the operation higher than for the transverse resolution screening targets at other depths. As revealed in figure beneath. Axial resolution ... Page 77 When using the convex probe, continue to keep the transverse resolution testing targets to NOTE: be exhibited close to the midline. When using a linear probe with steer purpose, tend not to turn on the steer operate when carry out the transverse resolution examination. Zoom within the region the place the targets Found if vital. The diameter in the goal issue at a specific depth is equivalent towards the transverse resolution on the depth. Webpage seventy eight five.

Click Agree and Continue to accept cookies and go on to the location or click on More details to determine comprehensive descriptions of the types of cookies and pick no matter whether to simply accept specified cookies even though on the positioning.

5.two.3 Geometric positioning precision Longitudinal geometric positioning accuracy  Check Move: Do changes as just how in screening the maximum depth. Record the gap by 20mm Every single segment over the longitudinal targets line using the measurement caliper; Decide on the worth with the best mistake (to 20mm), work out the precision utilizing the method beneath The measurement caliper ought to be positioned within the upper edge of the concentrate on, Be aware:... Web site 79 Transverse geometric positioning accuracy  Take a look at Step: Address the scan surface area with the phantom with water or couple gel, gently contact the probe with the scan surface area Change the depth, creating the transverse targets being exhibited inside the impression. Regulate the main focus issue to get posited beside the transverse targets (the conventional isn't crystal clear) Change parameters like attain, TGC, creating Every single transverse targets being Plainly shown. Website page eighty 5.5.2.four Blackout Place Exam Move: Cover the scan area of the phantom with h2o or few gel, gently Get in touch with the probe Together with the scan floor Modify the depth at a lessen price, and established the main target at the nearest destination to the scan surface. Lower the value of parameters like AP, Acquire right until the background sound just might be observed. Web page eighty one: Program Enhance And Upkeep